LEGALDIGMLEGALDIGM
    ← Ontario, Canada
    Beta
    ON:070213:en

    ON:070213:en — FIRE CODE

    Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.

    Analyze this law with AI
    Fire Protection and Prevention Act, 1997 ONTARIO REGULATION 213/07 fire code Consolidation Period: From January 1, 2026 to the e-Laws currency date . Last amendment: 303/25 . Legislative History: 150/13 , 194/14 , 256/14 , 275/14 , 108/18 , 33/19 , 319/22 , 87/25 , 303/25 . This is the English version of a bilingual regulation. division a compliance, objectives and functional statements PART 1 compliance and General SECTION 1.1 organization of this code Subsection 1.1.1. General Scope of Division A 1.1.1.1. Division A contains the compliance and application provisions, objectives and functional statements of this Code. Scope of Division B 1.1.1.2. Division B contains the acceptable solutions of this Code. Scope of Division C 1.1.1.3. Division C contains the administrative provisions of this Code. Internal cross-references 1.1.1.4. If a provision of this Code contains a reference to another provision of this Code but no Division is specified, both provisions are in the same Division of this Code. SECTION 1.2 COMPLIANCE Subsection 1.2.1. Compliance with this Code Owner’s responsibility 1.2.1.1. Unless otherwise specified, the owner is responsible for carrying out the provisions of this Code. Compliance with Parts 2 and 3 1.2.1.2. Compliance with Parts 2 and 3 is required only as it relates to the use of alternative solutions as set out in Subsection 1.2.2. Subsection 1.2.2. Compliance with Division B 1.2.2.1. (1) Compliance with Division B shall be achieved (a)  by complying with the acceptable solutions in Division B, or (b)  by using alternative solutions that (i)  will achieve the level of performance required by the applicable acceptable solutions in respect of the objectives and functional statements attributed to the applicable acceptable solutions in OFM Fire Code Supplement FCS-1, “Objectives and Functional Statements Attributed to Acceptable Solutions”, (ii)  do not contravene any other provision in Division B, and (iii)  have been approved and implemented in conformance with Subsection 1.3.2. of Division C. (2) For the purpose of Clause (1)(b), the level of performance in respect of a functional statement refers to the performance required by the functional statement as it relates to the objective with which it is associated in OFM Fire Code Supplement FCS-1, “Objectives and Functional Statements Attributed to Acceptable Solutions”. (3) The use of alternative solutions as described in Clause (1) (b) is not applicable in respect of any acceptable solutions to which objectives and functional statements have not been attributed in OFM Fire Code Supplement FCS-1, “Objectives and Functional Statements Attributed to Acceptable Solutions”. Subsection 1.2.3. Compliance with Other Applicable Law Compliance with other applicable law 1.2.3.1. Compliance with this Code does not relieve the owner from compliance with other applicable Acts and regulations, and, where a requirement of an applicable Act or regulation conflicts with a requirement of this Code, the more stringent requirement prevails, unless the more stringent requirement is in this Code and this Code says that the requirement of the other Act or regulation prevails. SECTION 1.3 exemptions Subsection 1.3.1. Exemption for Farms Exemption 1.3.1.1. (1) Subject to Sentence (2) and Article 1.3.1.2., a farm building with an occupant load of not more than one person per 40 m 2 of floor area during normal use and other premises on a farm used for farming purposes are exempt from the requirements of this Code. (2) Where a floor area or portion of a floor area within a farm building contains a hazardous extraction operation involving cannabis, the floor area or portion of the floor area shall comply with Articles 2.7.1.1. and 2.7.2.2., Section 2.8, Part 4, Article 5.1.4.2. and Subsection 5.14.11. of Division B. Where compliance required 1.3.1.2. (1) A farm building shall comply with Part 2 and Part 6 of Division B if it is (a)  more than 600 m 2 in building area or more than 3 storeys in building height , and (b)  constructed on or after January 1, 2025 to meet the requirements of the Building Code , as it read on or after that day, that apply to farm buildings . SECTION 1.4 terms and abbreviations Subsection 1.4.1. Definitions of Words and Phrases Non-defined terms 1.4.1.1. (1) Definitions of words and phrases used in this Code that are not included in the list of definitions in Article 1.4.1.2. have the meanings that are commonly assigned to them in the context in which they are used, taking into account the specialized use of terms with the various trades and professions to which the terminology applies. (2) Despite Sentence (1), words and phrases may be assigned other meanings where specifically noted in another provision of this Code. Defined terms 1.4.1.2. The words and terms used in this Code that are in bold face, and either in upper and lower case or in lower case, have the following meanings: Acceptable solution means a requirement set out in Division B. (“ solution acceptable”) Access to exit means that part of a means of egress within a floor area that provides access to an exit serving the floor area . (“accès à l’issue”) Agricultural occupancy means the occupancy of a building or part thereof that is located on land that is associated with and devoted to the practice of farming and is used for the purpose of producing crops, raising farm animals or preparing, marketing, storing or processing agricultural products. (“établissement agricole ”) Agricultural occupancy with no human occupants means an agricultural occupancy that is not intended to be occupied by persons under normal use and is generally used for the storage of agricultural materials and by-products. (“établissement agricole sans occupation humaine”) Air-supported structure means a structure that consists of a pliable membrane that achieves and maintains its shape and support by internal air pressure. (“structure gonflable”) Alarm signal means an audible signal transmitted throughout a zone or zones or throughout a building to advise occupants that a fire emergency exists. (“signal d’alarme”) Alert signal means an audible signal to advise designated persons of a fire emergency. (“signal d’alerte”) Alternative solution means a substitute for an acceptable solution . (“solution de rechange”) Appliance means a device to convert fuel into energy, and includes all components, controls, wiring and piping required to be part of the device by the applicable standard referred to in this Code. (“appareil”) Approved means approved by the Chief Fire Official . (“approuvé”) Architect means a member or licensee of the Ontario Association of Architects under the Architects Act . (“architecte”) Assembly occupancy means the occupancy or the use of a building , or part thereof, by a gathering of persons for civic, political, travel, religious, social, educational, recreational or like purposes or for the consumption of food or drink. (“établissement de reunion”) Atmospheric storage tank means a storage tank that is designed to operate at pressures from atmospheric to 3.5 kPa (gauge). (“réservoir de stockage sous pression atmosphérique”) Attic space means the space between the roof and the ceiling of the top storey or between a dwarf wall and a sloping roof. (“comble”) Basement means a storey or storeys of a building located below the first storey . (“sous-sol”) Boiler means an appliance intended to supply hot water or steam for space heating , processing or power purposes. (“chaudière”) Breeching means a flue pipe or chamber for receiving flue gases from one or more flue connections and for discharging these gases through a single flue connection. (“collecteur de fumée”) Building means any structure used or intended for supporting or sheltering any use or occupancy . (“bâtiment”) Building area means the greatest horizontal area of a building above grade within the outside surface of exterior walls or within the outside surface of exterior walls and the centre line of firewalls . (“aire de bâtiment”) Building Code means any version of the Ontario Building Code that was in force at any time since it was made under The Building Code Act, 1974 , the Building Code Act of the Revised Statutes of Ontario, 1980, the Building Code Act of the Revised Statutes of Ontario, 1990, the Building Code Act, 1992 or a successor to the Building Code Act, 1992 , and, where a specific version of the Building Code is referred to, that version of the Building Code . (“code du bâtiment”) Building height (in storeys ) means the number of storeys contained between the roof and the floor of the first storey . (“hauteur de bâtiment”) Business and personal services occupancy means the occupancy or use of a building or part thereof for the transaction of business or the rendering or receiving of professional or personal services. (“établissement d’affaires”) Care and treatment occupancy means an occupancy in which persons receive special care and treatment. (“établissement de soins et de traitement”) Care occupancy means an occupancy in which special care is provided by a facility, directly through its staff or indirectly through another provider, to residents of the facility (a)  who require special care because of cognitive or physical limitations, and (b)  who, as a result of those limitations, would be incapable of evacuating the occupancy , if necessary, without the assistance of another person. (“ établissement de soins”) Check means visual observation to ensure the device or system is in place and is not obviously damaged or obstructed. (“verification”) Chief Fire Official means the assistant to the Fire Marshal who is the Municipal Fire Chief or a member or members of the fire department appointed by the Municipal Fire Chief under Article 1.1.1.2. of Division C or a person appointed by the Fire Marshal under Article 1.1.1.1. of Division C. (“chef de la sécurité-incendie”) Chimney means a primarily vertical shaft enclosing at least 1 flue for conducting flue gases to the outdoors. (“cheminée”) Class A fire means a fire involving combustible materials such as wood, cloth and paper. (“feu de classe A”) Class B fire means a fire involving a flammable or combustible liquid , fat or grease. (“feu de classe B”) Class C fire means a fire involving energized electrical equipment. (“feu de classe C”) Class D fire means a fire involving a combustible metal. (“feu de classe D”) Class K fire means a fire involving combustible cooking media such as vegetable oils, animal oils and animal fats. (“feu de classe K”) Closed container means a container so sealed by means of a lid or other device that neither liquid nor vapour will escape from it at ordinary temperatures. (“récipient fermé”) Closure means a device or assembly for closing an opening through a fire separation , an exterior wall or an opening onto a fire escape that is required to be protected, which (a)  may include a door, a shutter, wired glass or glass block, and (b)  includes all components, such as hardware, closing devices, frames and anchors. (“ dispositif d’obturation”) Combustible construction means that type of construction that does not meet the requirements for noncombustible construction or encapsulated mass timber construction . (“ construction combustible”) Combustible dust means dust and particles that are ignitable and liable to produce an explosion. (“ poussière combustible”) Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth. (“fibres combustibles”) Combustible liquid means any liquid having a flash point at or above 37.8°C and below 93.3°C. (“liquide combustible”) Compressed gas means any contained mixture or material with either an absolute pressure exceeding 275.8 kPa at 21°C or an absolute pressure exceeding 717 kPa at 54°C, or both, or any liquid having an absolute vapour pressure exceeding 275.8 kPa at 37.8°C. (“gaz comprimé”) Contained use area means a supervised area containing one or more rooms in which occupant movement is restricted to a single room by security measures not under the control of the occupant. (“zone de détention cellulaire”) Dangerous goods means products, materials or substances that are (a)  regulated by the Transportation of Dangerous Goods Regulations , SOR/2001-286, made under the Transportation of Dangerous Goods Act (Canada) , or (b)  classified as hazardous products under the Hazardous Products Regulations , SOR/2015-17, made under the Hazardous Products Act (Canada) . (“marchandises dangereuses”) Demolition means the doing of anything in the removal of a building or any material part thereof. (“demolition”) Detention occupancy means an occupancy in which persons are under restraint or are incapable of self preservation because of security measures not under their control. (“établissement de detention”) Dispenser sump means a liquid-tight container intended for installation under a dispensing unit for the collection of any internal leakage of flammable liquid or combustible liquid from the dispensing unit. (“puisard de distributeur”) Distilled beverage alcohol means a beverage that is produced by fermentation and contains more than 20 per cent by volume of water-miscible alcohol. (“boisson alcoolique distillée”) Distillery means a process plant where distilled beverage alcohols are produced, concentrated or otherwise processed, and includes facilities on the same site where the concentrated products may be blended, mixed, stored or packaged. (“distillerie”) Dwelling unit means a suite operated as a housekeeping unit, used or intended to be used by one or more persons and usually containing cooking, eating, living, sleeping and sanitary facilities, and includes a residential unit . (“logement”) Encapsulated mass timber construction means that type of construction in which a degree of fire safety is attained by the use of encapsulated mass timber elements with an encapsulation rating and minimum dimensions for structural members and other building assemblies. (“construction en bois d’œuvre massif encapsule”) Encapsulation rating means the time in minutes that a material or assembly of materials will delay the ignition and combustion of encapsulated mass timber elements when it is exposed to fire under specified conditions of test and performance criteria. (“degré d’encapsulation”) Exit means that part of a means of egress , including doorways, that leads from the floor area it serves to a separate building , an open public thoroughfare or an exterior open space protected from fire exposure from the building and having access to an open public thoroughfare. (“issue”) Facility , for the purposes of Division A, means a property upon which a use regulated by this Code, including open air public assembly activities, open air industrial processing and outdoor storage, occurs, whether or not a building is located on the property. (“installation”) Farm building means a building or part thereof that contains an agricultural occupancy . (“ bâtiment agricole”) Fire compartment means an enclosed space in a building that is separated from all other parts of the building by enclosing construction that provides a fire separation having a required fire-resistance rating . (“compartiment résistant au feu”) Fire damper means a closure that consists of a damper installed in an air distribution system or in a wall or floor assembly that is normally held in the open position and that is designed to close automatically in the event of a fire in order to maintain the integrity of the fire separation . (“registre coupe-feu”) Fire department means a group of firefighters authorized to provide fire protection services by a municipality, group of municipalities or by an agreement made under section 3 of the Fire Protection and Prevention Act, 1997 . (“service d’incendie”) Fire detector means a device which detects a fire condition and automatically initiates an electrical signal to actuate an alert signal or alarm signal and includes heat detectors and smoke detectors . (“détecteur d’incendie”) Fire-protection rating means the time in hours or fraction thereof that a closure , window assembly or glass block assembly will withstand the passage of flame when exposed to fire under specified conditions of test and performance criteria, or as otherwise prescribed in the Building Code . (“degré pare-flammes”) Fire-resistance rating means the time in hours or fraction thereof that a material or assembly of materials will withstand the passage of flame and the transmission of heat when exposed to fire under specified conditions of test and performance criteria, or as determined by extension or interpretation of information derived therefrom as prescribed in the Building Code . (“degré de résistance au feu”) Fire separation means a construction assembly that acts as a barrier against the spread of fire. (“ séparation coupe-feu”) Fire stop means a draft-tight barrier within or between construction assemblies that acts to retard the passage of smoke and flame. (“coupe-feu”) Fire stop flap means a device intended for use in horizontal assemblies that are required to have a fire-resistance rating and incorporate protective ceiling membranes and that operates to close off a duct opening through the membrane in the event of a fire. (“clapet coupe-feu”) Firewall means a fire separation of noncombustible construction that subdivides a building or separates adjoining buildings to resist the spread of fire that has a fire-resistance rating as prescribed in the Building Code and that has structural stability to remain intact under fire conditions for the required fire-rated time. (“mur coupe-feu”) First storey means the storey with its floor closest to grade and having its ceiling more than 1.8 m above grade . (“premier étage”) Flame-spread rating means an index or classification indicating the extent of spread of flame on the surface of a material or an assembly of materials as determined in a standard fire test as prescribed in the Building Code . (“ indice de propagation de la flamme”) Flammable liquid means a liquid having a flash point below 37.8ºC and having a vapour pressure not more than 275.8 kPa (absolute) at 37.8ºC as determined by ASTM D 323, “Vapor Pressure of Petroleum Products (Reid Method)”. (“liquide inflammable”) Flash point means the minimum temperature at which a liquid within a container gives off vapour in sufficient concentration to form an ignitable mixture with air near the surface of the liquid. (“point d’éclair”) Floor area means the space on any storey of a building between exterior walls and required firewalls , including the space occupied by interior walls and partitions , but not including exits , vertical service spaces and their enclosing assemblies. (“ aire de plancher”) Flue means an enclosed passageway for conveying exhaust gases. (“conduit de fumée”) Flue collar means the portion of a fuel-fired appliance designed for the attachment of the flue pipe or breeching . (“buse”) Flue pipe means the pipe connecting the flue collar of an appliance to a chimney . (“ tuyau de raccordement”) Fuel-dispensing station means any premises or part of premises at which flammable liquids or combustible liquids are dispensed from fixed equipment into the fuel tank of a motor vehicle, watercraft or floatplane. (“poste de distribution de carburant”) Functional statement means a function set out in Part 3. (“énoncé fonctionnel”) Furnace means a space-heating appliance that uses warm air as the heating medium and that usually has provision for the attachment of ducts. (“générateur d’air chaud”) Grade means the average level of finished ground adjoining a building at all exterior walls. (“niveau moyen du sol”) Guest suite means a single room or a series of rooms of complementary use providing sleeping accommodation for the travelling public or for recreational purposes in a hotel establishment . (“suite pour invites”) Hazardous extraction means a process to remove or separate a substance from a solution or mixture that involves the use of flammable liquids , combustible liquids or flammable gases as solvents in the process. (“extraction dangereuse”) Heat detector means a fire detector designed to operate at a predetermined temperature or rate of temperature rise. (“détecteur de chaleur”) Heavy timber construction means that type of combustible construction in which a degree of fire safety is attained by placing limitations on the sizes of wood structural members and on thickness and composition of wood floors and roofs, by avoidance of concealed spaces under floors and roofs and by use of approved fastenings, construction details and adhesives for structural members. (“construction en gros bois d’œuvre”) High-hazard agricultural occupancy means an agricultural occupancy containing sufficient quantities of highly combustible and flammable or explosive materials which, because of their inherent characteristics, constitute a special fire hazard. (“établissement agricole à risques très élevés”) High-hazard industrial occupancy means an industrial occupancy that contains sufficient quantities of highly combustible and flammable or explosive materials that, because of their inherent characteristics, constitute a special fire hazard. (“établissement industriel à risques très élevés”) Hotel means floor areas , a floor area or part of a floor area containing four or more suites that provide sleeping accommodation for the travelling public or for recreational purposes. (“hôtel”) Hotel establishment means a building containing a hotel and all subsidiary occupancies that are operated in connection with the hotel and includes all connected or adjacent buildings that are operated in connection with the hotel . (“établissement hotelier”) Impeded egress zone means a supervised area in which occupants have free movement but require the release, by security personnel, of security doors at the boundary before they are able to leave the area, but does not include a contained use area . (“zone à sortie contrôlée”) Individual storage area means the area occupied by piles, bin boxes, racks or shelves, including subsidiary aisles providing access to the stored products, which is separated from the adjacent storage by aisles. (“îlot de stockage”) Industrial occupancy means the occupancy or use of a building or part thereof for assembling, fabricating, manufacturing, processing, repairing or storing of goods and materials. (“établissement industriel”) Inspection means physical examination to determine that the device or system will apparently perform in accordance with its intended function. (“inspection”) Interconnected floor space means superimposed floor areas or parts of floor areas in which floor assemblies that are required to be fire separations are penetrated by openings that are not provided with closures . (“aire communicante”) Listed means equipment or materials included in a list published by a certification organization accredited by the Standards Council of Canada. (“répertorié”) Low-hazard industrial occupancy means an industrial occupancy in which the combustible content is not more than 50 kg/m 2 or 1200 MJ/m 2 of floor area . (“établissement industriel à risques faibles”) Low pressure storage tank means a storage tank designed to operate at pressures greater than 3.5 kPa (gauge) to 100 kPa (gauge). (“réservoir de stockage sous basse pression”) Lower explosive limit means the minimum concentration of vapour in air at which the propagation of flame occurs on contact with a source of ignition. (“limite inférieure d’explosivité”) Major occupancy means the principal occupancy for which a building or part thereof is used or intended to be used, and includes the subsidiary occupancies that are an integral part of the principal occupancy . (“usage principal”) Marine fuel-dispensing station means a fuel-dispensing station at which flammable liquids or combustible liquids are dispensed into the fuel tank of a watercraft or floatplane. (“poste marin de distribution de carburant”) Means of egress means a continuous path of travel provided for the escape of persons from any point in a building or contained open space to a separate building , an open public thoroughfare or an exterior open space protected from fire exposure from the building and having access to an open public thoroughfare. Means of egress includes both exits and access to exits . (“moyen d’évacuation”) Medium-hazard industrial occupancy means an industrial occupancy in which the combustible content is more than 50 kg/m 2 or 1200 MJ/m 2 of floor area and not classified as high-hazard industrial occupancy . (“établissement industriel à risques moyens”) Mercantile occupancy means the occupancy or use of a building or part thereof for the displaying or selling of retail goods, wares or merchandise. (“établissement commercial”) Minimum explosible concentration (MEC) means the minimum concentration of combustible dust suspended in air, measured in mass per unit volume, that will support a deflagration as defined by the test procedure in ASTM E 1515, “Standard Test Method for Minimum Explosible Concentration of Combustible Dusts”. (“concentration explosive minimale”) Noncombustible construction means that type of construction in which a degree of fire safety is attained by the use of noncombustible materials for structural members and other building assemblies. (“construction incombustible”) Objective means an objective set out in Part 2. (“ objectif”) Occupancy means the use or intended use of a building or part thereof for the shelter or support of persons, animals or property. (“usage”) Occupant load means the number of persons for which a building or part thereof is designed. (“nombre d’occupants”) Order means an order made under subsection 21(1) of the Fire Protection and Prevention Act, 1997 . (“ordre”) Owner means any person, firm or corporation having control over any portion of the building or property under consideration and includes the persons in the building or property. (“propriétaire”) Partition means an interior wall, one storey or part of a storey in height, that is not load-bearing. (“cloison”) Plenum means a chamber forming part of an air duct system. (“plenum”) Pressure vessel means a storage tank that is designed to operate at pressures greater than 100 kPa (gauge). (“récipient sous pression”) Process plant means an industrial occupancy where materials, including flammable liquids , combustible liquids or Class 2 gases, are produced or used in a process. (“usine de transformation”) Professional Engineer means a person who holds a licence or a temporary licence under the Professional Engineers Act . (“ ingénieur”) Public amusement area means an area where the public is ordinarily invited or permitted access, either expressly or by implication, whether or not a fee is charged for entry, and includes entertainment displays or structures used on a temporary, seasonal or permanent basis. (“aire de divertissement public”) Public corridor means a corridor that provides access to exit from more than one suite . (“corridor commun”) Rack means any combination of vertical, horizontal or diagonal members that support stored materials on solid or open shelves, including both fixed and portable units. (“rayonnage”) Rapid transit station means a building or part thereof used for the purpose of loading and unloading passengers of a rapid transit system but does not include open-air shelters at street level. (“station de transport rapide”) Refinery means any process plant in which flammable or combustible liquids are produced from crude petroleum, including areas on the same site where the resulting products are blended, packaged or stored on a commercial scale. (“raffinerie”) Refuse storage room means a room in a building that is used for the storage of combustible refuse, including waste materials and recyclables. (“salle de stockage des déchets”) Residential occupancy means an occupancy in which sleeping accommodation is provided to residents who are not harboured for the purpose of receiving special care or treatment and are not involuntarily detained. (“habitation”) Residential unit means a suite operated as a housekeeping unit, used or intended to be used by one or more persons that contains cooking, eating, living, sleeping and sanitary facilities. (“unité d’habitation”) Retirement home means a retirement home regulated under the Retirement Homes Act, 2010 . (“maison de retraite”) Retrofit means the minimum performance requirements for life safety for existing buildings . (“réaménagement”) Self-service outlet means a fuel-dispensing station , other than a marine fuel-dispensing station , where the public handles the dispenser. (“poste de distribution libre-service”) Self-service storage building means a building that is used to provide individual storage spaces to the public and that is open to the public only for those purposes. (“bâtiment de stockage libre-service”) Service room means a room in a building used to contain equipment associated with building services. (“local technique”) Service space means space in a building used to facilitate or conceal the installation of building service facilities such as chutes, ducts, pipes, shafts or wires. (“vide technique”) Smoke alarm means a combined smoke detector and audible alarm device that is designed to sound an alarm within the room or suite in which it is located when there is smoke within the room or suite . (“avertisseur de fumée”) Smoke detector means a fire detector designed to operate when the concentration of airborne combustion products exceeds a predetermined level. (“détecteur de fumée”) Space heater means a space-heating appliance that heats the room or space within which it is located without the use of ducts. (“poêle”) Space-heating appliance means an appliance that supplies heat to a room or space directly or indirectly or to rooms or spaces of a building through a heating system. (“générateur de chaleur”) Spill containment sump means a liquid-tight container intended to catch, retain and provide for the evacuation of any product at the time of filling. (“puisard de confinement des déversements”) Spraying area means the area that is within 6 m of a spray booth or spraying operation and that is not separated therefrom by a vapour-tight separation. (“aire de pulvérisation”) Spray booth means a power-ventilated structure that encloses or accommodates a spraying operation so that spray vapour and residue can be controlled and exhausted. (“cabine de pulvérisation”) Spray room means a spraying area on a floor area or part thereof in which an open spraying operation is confined and that is separated from the remainder of the building in which it is located by a noncombustible vapour-tight separation. (“atelier de pulvérisation”) Sprinklered (as applying to a building or part thereof) means that the building or part thereof is equipped with a system of automatic sprinklers. (“protégé par gicleurs”) Storage garage means a building or part of a building that is intended for the storage or parking of motor vehicles and that contains no provision for the repair or servicing of motor vehicles. (“ garage de stationnement”) Storage tank means a vessel for flammable liquids or combustible liquids having a capacity of more than 230 L and designed to be installed in a fixed location. (“ réservoir de stockage”) Storey means that portion of a building that is situated between the top of any floor and the top of the floor next above it, and where there is no floor above it, that portion between the top of the floor and the ceiling above it. (“étage”) Street means any highway, road, boulevard, square or other improved thoroughfare 9 m or more in width that has been dedicated or deeded for public use and is accessible to fire department vehicles and equipment. (“rue”) Suite means a single room or series of rooms of complementary use, operated under a single tenancy, and includes dwelling units , individual guest rooms in motels, hotels , boarding houses, rooming houses and dormitories, as well as individual stores and individual or complementary rooms for business and personal services occupancies . (“ suite ”) Supervisory staff means those occupants of a building who have some delegated responsibility for the fire safety of other occupants under the fire safety plan. (“ personnel de surveillance”) Tank vehicle means any vehicle, other than railroad tank cars and boats, with a cargo tank having a capacity of more than 450 L mounted or built as an integral part of the vehicle, used for the transportation of flammable or combustible liquids , and includes tank trucks, trailers and semi-trailers. (“véhicule-citerne”) Tent means a shelter or structure with a covering that is made of pliable material. (“tente”) Test means the operation of a device or system to ensure that it will perform in accordance with its intended operation or function. (“essai”) Total area means the total area of all floors above and below grade , including mezzanines and penthouses, measured between the inside surfaces of exterior walls or between the inside surfaces of exterior walls and the inside surfaces of firewalls . (“superficie totale”) Transition sump means an underground liquid-tight container intended for installation where mechanical connection or transition takes place for the collection of any internal leakage of flammable liquid or combustible liquid . (“puisard de transition”) Travel distance means the distance from any point in a floor area to an exit measured along the path of exit travel, except that when floor areas are subdivided into rooms used singly or into suites of rooms and served by public corridors or exterior passageways, the distance is measured from the door of the rooms or suites to the nearest exit . (“ distance à franchir”) Turbine sump means a container designed to provide access to equipment and to contain minor leakage, and installed to prevent water ingress.(“puisard de turbine”) Unstable liquid means a liquid, including a flammable liquid or combustible liquid , which is chemically reactive to the extent that it will vigorously react or decompose at or near normal temperature and pressure conditions or which is chemically unstable when subject to impact. (“ liquide instable”) Vapour pressure means the pressure exerted by a liquid as determined by ASTM D 323, “Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method)”. (“ pression de vapeur”) Vertical service space means a shaft oriented essentially vertically that is provided in a building to facilitate the installation of building services, including mechanical, electrical and plumbing installations and facilities such as elevators, refuse chutes and linen chutes. (“ vide technique vertical”) Viscosity means the resistance that a liquid offers to flow. (“viscosité”) Subsection 1.4.2. Symbols and Other Abbreviations 1.4.2.1. The symbols and abbreviations in this Code have the following meanings: cm centimetre(s) cm/s centimetre(s) per second cm 2 square centimetre(s) °C degree(s) Celsius h hour(s) kg kilogram(s) kN kilonewton(s) kPa kilopascal(s) L litre(s) L/h litre(s) per hour L/min litre(s) per minute L/min/m 2 litre(s) per minute per square metre lx lux m metre(s) m 2 square metre(s) m 3 cubic metre(s) m/s metre(s) per second m/min metre(s) per minute m 3 /h cubic metre(s) per hour m 3 /min cubic metre(s) per minute min minute(s) MJ megajoule(s) mL millilitre(s) mm millimetre(s) mm 2 /s square millimetre(s) per second N newton(s) ppm part(s) per million s second(s) t tonne(s) % per cent SECTION 1.5 referenced documents Subsection 1.5.1. Referenced Documents Application of referenced documents 1.5.1.1. The provisions of documents referenced in this Code apply only to the extent that they are related to fire safety matters or to the risk created by the presence of unsafe levels of carbon monoxide. Conflicting requirements 1.5.1.2. In the case of a conflict between the provisions of this Code and those of a referenced document, the provisions of this Code prevail. Secondary references 1.5.1.3. If a document in this Code refers to another document, only those portions of the second document that are specific to the subject matter are applicable. O. Reg. 213/07, Division A, Part 1; O. Reg. 150/13, s. 1; O. Reg. 194/14, ss. 1, 2; O. Reg. 256/14, ss. 1-3; O. Reg. 33/19, ss. 1-3; O. Reg. 87/25, ss. 1, 2, 95; O. Reg. 303/25, s. 1. PART 2 objectives SECTION 2.1 application Subsection 2.1.1. Application 2.1.1.1. (1) The objectives set out in Table 2.2.1.1. apply only to the extent that they relate to an alternative solution as provided in Article 1.2.2.1. (2) The objectives described in this Part apply only as they relate to fire safety or to the risk created by the presence of unsafe levels of carbon monoxide. SECTION 2.2 objectives Subsection 2.2.1. Objectives 2.2.1.1. The objectives of this Code are those listed in Table 2.2.1.1. TABLE 2.2.1.1. Objectives Forming Part of Article 2.2.1.1. Column 1 Category Column 2 Objective number Column 3 Objective SAFETY OS An objective of this Code is to limit the probability that, as a result of specific circumstances related to the building or facility , a person in or adjacent to the building or facility will be exposed to an unacceptable risk of injury. Fire Safety OS1 An objective of this Code is to limit the probability that, as a result of (a)  activities related to the construction, use or demolition of the building or facility , (b)  the condition of specific elements of the building or facility , (c)  the design and construction of specific elements of the facility related to certain hazards, or (d)  inadequate built-in protection measures for the current or intended use of the building , a person in or adjacent to the building or facility will be exposed to an unacceptable risk of injury due to fire. The risks of injury due to fire addressed in this Code are those caused by: OS1.1 fire or explosion occurring OS1.2 fire or explosion impacting areas beyond its point of origin OS1.3 collapse of physical elements due to a fire or explosion OS1.4 fire safety systems failing to function as expected OS1.5 persons being delayed in or impeded from moving to a safe place during a fire emergency Safety in Use OS3 An objective of this Code is to limit the probability that, as a result of (a)  activities related to the construction, use or demolition of the building or facility , (b)  of specific elements of the building or facility , (c)  the design and construction of specific elements of the facility related to certain hazards, or (d)  inadequate built-in protection measures for the current or intended use of the building , a person in or adjacent to the building or facility will be exposed to an unacceptable risk of injury due to hazards. The risks of injury due to hazards addressed in this Code are those caused by: OS3.1 tripping, slipping, falling, contact, drowning or collision OS3.2 contact with hot surfaces or substances OS3.3 contact with energized equipment OS3.4 exposure to hazardous substances OS3.7 persons being delayed in or impeded from moving to a safe place during an emergency HEALTH OH An objective of this Code is to limit the probability that, as a result of specific circumstances related to the building or facility , a person will be exposed to an unacceptable risk of illness. Indoor Conditions OH1 An objective of this Code is to limit the probability that, as a result of an installation required by this Code, a person in the building or facility will be exposed to an unacceptable risk of illness due to indoor conditions. The risks of illness due to indoor conditions addressed in this Code are those caused by: OH1.1 inadequate indoor air quality Hazardous Substances Containment OH5 An objective of this Code is to limit the probability that, as a result of (a)  activities related to the construction, use or demolition of the building or facility , (b)  the condition of specific elements of the building or facility , (c)  the design and construction of specific elements of the facility related to certain hazards, or (d)  inadequate built-in protection measures for the current or intended use of the building , the public will be exposed to an unacceptable risk of illness due to the release of hazardous substances from the building or facility . Fire Protection of Buildings and Facilities OP An objective of this Code is to limit the probability that, as a result of specific circumstances related to the building or facility , the building or facility will be exposed to an unacceptable risk of damage due to fire. Fire Protection of the Building or Facility OP1 An objective of this Code is to limit the probability that, as a result of (a)  activities related to the construction, use or demolition of the building or facility , (b)  the condition of specific elements of the building or facility , (c)  the design and construction of specific elements of the facility related to certain hazards, or (d)  inadequate built-in protection measures for the current or intended use of the building , the building or facility will be exposed to an unacceptable risk of damage to due to fire. The risks of damage due to fire addressed in this Code are those caused by: OP1.1 fire or explosion occurring OP1.2 fire or explosion impacting areas beyond its point of origin OP1.3 collapse of physical elements due to a fire or explosion OP1.4 fire safety systems failing to function as expected Protection of Adjacent Buildings or Facilities from Fire OP3 An objective of this Code is to limit the probability that, as a result of (a)  activities related to the construction, use or demolition of the building or facility , (b)  the condition of specific elements of the building or facility , (c)  the design and construction of specific elements of the facility related to certain hazards, or (d)  inadequate built-in protection measures for the current or intended use of the building , adjacent buildings or facilities will be exposed to an unacceptable risk of damage to due to fire. The risks of damage due to fire addressed in this Code are those caused by: OP3.1 fire or explosion impacting areas beyond the building or facility of origin O. Reg. 213/07, Division A, Part 2; O. Reg. 33/19, s. 4. PART 3 functional statements SECTION 3.1 application Subsection 3.1.1. Application 3.1.1.1. The functional statements set out in Table 3.2.1.1. apply only to the extent that they relate to an alternative solution as provided in Article 1.2.2.1. SECTION 3.2 functional statements Subsection 3.2.1. Functional Statements 3.2.1.1. The functional statements of this Code are those set out in Table 3.2.1.1. Table 3.2.1.1. Functional Statements Forming Part of Article 3.2.1.1. Column 1 Function Column 2 Functional Statement F01 To minimize the risk of accidental ignition. F02 To limit the severity and effects of a fire or explosion. F03 To retard the effects of fire on areas beyond its point of origin. F04 To retard failure or collapse due to the effects of fire. F05 To retard the effects of fire on emergency egress facilities . F06 To retard the effects of fire on facilities for notification, suppression and emergency response. F10 To facilitate the timely movement of persons to a safe place in an emergency. F11 To notify persons, in a timely manner, of the need to take action in an emergency. F12 To facilitate emergency response. F13 To notify emergency responders, in a timely manner, of the need to take action in an emergency. F20 To support and withstand expected loads and forces. F21 To limit or accommodate dimensional change. F22 To limit movement under expected loads and forces. F30 To minimize the risk of injury to persons as a result of tripping, slipping, falling, contact, drowning or collision. F32 To minimize the risk of injury to persons as a result of contact with energized equipment. F34 To resist or discourage unwanted access or entry. F36 To minimize the risk that persons will be trapped in confined spaces. F43 To minimize the risk of release of hazardous substances. F44 To limit the spread of hazardous substances beyond their point of release. F51 To maintain appropriate air and surface temperatures. F80 To resist deterioration resulting from expected service conditions. F81 To minimize the risk of malfunction, interference, damage, tampering, lack of use or misuse. F82 To minimize the risk of inadequate performance due to improper maintenance or lack of maintenance. O. Reg. 213/07, Division A, Part 3; O. Reg. 33/19, s. 5. division b acceptable solutions PART 1 GENERAL SECTION 1.1 General Subsection 1.1.1. General Notification 1.1.1.1. Where tests , repairs or alterations are made to fire protection installations, including sprinkler and standpipe systems, a procedure of notification shall be established, and the procedure shall include notifying the fire department and the building occupants where necessary for safety in the event of a fire emergency. Check, inspect and test 1.1.1.2. (1) The checking , inspection and testing of fire safety devices shall be conducted in accordance with this Code. (2) Where specific references to checking , inspection and testing of fire safety devices are not made in this Code, such devices shall be maintained to ensure they operate as per their design requirements. (3) Any appliance , device or component of a device that does not operate or appear to operate as intended when checked , inspected or tested as required by this Code shall be repaired or replaced if the failure or malfunctioning of the appliance , device or component would adversely affect fire or life safety. Subsection 1.1.2. Records of Tests and Inspections Making of records 1.1.2.1. (1) If this Code requires tests and corrective measures or operational procedures to be carried out, records shall be made noting what was done and the date and time it was done. (2) If this Code requires an inspection to be conducted in a supported group living residence or an intensive support residence regulated under the Services and Supports to Promote the Social Inclusion of Persons with Developmental Disabilities Act, 2008 , a record shall be made noting what was inspected and the date and time of the inspection . (3) The records described in Sentences (1) and (2) shall be retained at the building premises for examination by the Chief Fire Official . (4) Electronic records that can be made readily available to the Chief Fire Official upon request, are deemed to comply with Sentence (3). Retention of records 1.1.2.2. (1) Subject to Sentence (2), the original or a copy of any record required by this Code shall be retained at the building to which the record relates (a)  for a period of at least two years after being prepared, and (b)  so that at least the most recent and the immediately preceding record of a given test or inspection are retained. (2) The initial verification or test reports for fire protection systems installed after November 21, 2007 shall be retained throughout the life of the systems, regardless of whether the systems are installed in accordance with this Code or the Building Code . SECTION 1.2 referenced documents and organizations Subsection 1.2.1. Referenced Documents Applicable editions 1.2.1.1. (1) A reference in this Code to a document set out in Table 1.2.1.A. is to the edition designated in the table. (2) Any appliance , equipment, system, installation or construction that met the requirements of this Article on December 31, 2025, as it read at the time, and that continues to meet those requirements is deemed to comply with the requirements of the edition referred to in Sentence (1). Effective date 1.2.1.2. Unless otherwise specified in this Code, the documents referenced in this Code shall include all amendments, revisions and supplements effective to January 1, 2026. Previous editions 1.2.1.3. Despite Articles 1.2.1.1. and 1.2.1.2., the Chief Fire Official may permit compliance with an edition of a document previous to that referred to in this Code if the Chief Fire Official is satisfied that compliance with the edition referred to in this Code is impractical. TABLE 1.2.1.A. Forming Part of Article 1.2.1.1. Issuing Agency Document Number Title of Document Code Reference API SPEC 5L (2012) Line Pipe 4.5.2.1.(4) API SPEC 12B (2008) Specification for Bolted Tanks for Storage of Production Liquids 4.3.1.2.(1) API SPEC 12D (2008) Specification for Field Welded Tanks for Storage of Production Liquids 4.3.1.2.(1) API SPEC 12F (2008) Specification for Shop Welded Tanks for Storage of Production Liquids 4.3.1.2.(1) API STD 620 (2013) Design and Construction of Large, Welded, Low-Pressure Storage Tanks 4.3.1.3.(1) API STD 650 (2013) Welded Tanks for Oil Storage 4.3.1.2.(1) API STD 653 (2009) Tank Inspection, Repair, Alteration, and Reconstruction 4.3.1.10.(2) Table 4.4.1.2.B. API STD 1104 (2013) Welding of Pipelines and Related Facilities 4.5.5.2.(1) 4.5.10.7.(6) API STD 2000 (2009) Venting Atmospheric and Low-Pressure Storage Tanks 4.3.1.2.(2) 4.3.4.1.(1) API RP 1604 (1996) Closure of Underground Petroleum Storage Tanks 4.3.16.1.(1) 4.3.16.6.(1) API RP 2200 (2010) Repairing Crude Oil, Liquefied Petroleum Gas and Product Pipelines 4.5.10.7.(6) API RP 2201 (2003) Safe Hot Tapping Practices in the Petroleum and Petrochemical Industries 4.5.10.7.(6) ASME B16.5-2017 Pipe Flanges and Flanged Fittings NPS ½ Through NPS 24 Metric/Inch Standard 4.5.5.3.(1) ASME B31.3-2016 Process Piping 4.5.2.1.(5) ASME BPVC-2017 Boiler and Pressure Vessel Code 4.3.1.3.(1) 4.5.9.5.(2) 4.5.9.6.(1) ASTM A53/A53M-18 Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless 4.5.2.1.(4) ASTM A193/A193M-17 Standard Specification for Alloy-Steel and Stainless Steel Bolting for High Temperature or High Pressure Service and Other Special Purpose Applications 4.5.5.4. ASTM D56-16a Standard Test Method for Flash Point by Tag Closed Cup Tester 4.1.3.1.(1) ASTM D93-18 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester 4.1.3.1.(2) ASTM D323-15a Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method) 1.4.1.2. of Division A (Vapour pressure) ASTM D3278-96 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus 4.1.3.1.(4) ASTM D3828-16a Standard Test Methods for Flash Point by Small Scale Closed Cup Tester 4.1.3.1.(3) ASTM E1515-14R22 Standard Test Method for Minimum Explosible Concentration of Combustible Dusts 1.4.1.2. of Division A (Minimum explosible concentration) CCBFC NRCC-CONST-56437E 2020 National Fire Code of Canada 2020 7.3.1.2. CCME PN 1326 (2003) Environmental Code of Practice for Aboveground and Underground Storage Tank Systems Containing Petroleum and Allied Petroleum Products 4.3.16.1.(1) 4.3.16.6.(1) CFA 1990 Using the Canadian Fuels Colour-Symbol System to Mark Equipment and Vehicles For Product Identification 4.3.1.7.(1) 4.5.4.1.(3) 4.5.7.6.(1) CGA P-1 (2008) Standard for Safe Handling of Compressed Gases in Containers 5.6.1.1.(3) CGSB CAN2-4.2-M77 Textile Test Methods 2.3.2.1.(2) CSA 6.19-01 Residential Carbon Monoxide Alarming Devices 2.16.2.1.(6) 6.3.4.7.(4) CSA B51 : 19 Boiler, Pressure Vessel and Pressure Piping Code 4.3.1.3.(2) CSA B108-18 Natural gas refuelling stations installation code 4.6.1.1.(2) CSA B139 Series:19 Installation code for oil-burning equipment 4.3.13.6. CSA B149.1-15 Natural Gas and Propane Installation Code 4.6.1.1.(2) CSA B149.2-15 Propane Storage and Handling Code 4.6.1.1.(2) CSA B306-M1977 Portable Fuel Tanks for Marine Use 4.2.3.1.(1) CSA B346-M1980 Power-Operated Dispensing Devices for Flammable Liquids 4.6.3.1. CSA B365-17 Installation Code for Solid-Fuel-Burning Appliances and Equipment 2.6.2.1. 2.6.2.2. CSA B376-M1980 Portable Containers for Gasoline and Other Petroleum Fuels 4.2.3.1.(1) CSA B620-14 Highway Tanks and TC Portable Tanks for the Transportation of Dangerous Goods 4.2.3.1.(1) CSA C22.2 No. 141-15 Emergency Lighting Equipment 9.9.5.5.(2) CSA C22.2 No.152-1984 (R2011) Combustible Gas Detection Instruments 5.17.3.3.(1) CSA C282-15 Emergency Electrical Power Supply for Buildings 6.7.1.1.(1) 6.7.1.3. 9.9.5.5.(1) and (2) CSA CAN/CSA- W117.2:19 Safety in Welding, Cutting and Allied Processes 5.17.1.2. CSA Z32-15 Electrical Safety and Essential Electrical Systems in Health Care Facilities 6.7.1.1.(2) CSA Z245.1-14 Steel Pipe 4.5.2.1.(4) CSA Z305.12-06 (R2021) Safe Storage, Handling, and Use of Portable Oxygen Systems in Residential Buildings and Health Care Facilities 2.15.1.2. IMO 2012 International Maritime Dangerous Goods Code 3.3.4.8. MMAH Supplementary Standard SB-4, January 1, 2024 Measures for Fire Safety in High Buildings 7.3.1.3.(2) NACE SP0285-2011-SG Corrosion Control of Underground Storage Tank Systems by Cathodic Protection 4.3.10.1.(1) NACE SP0169-2013 Control of External Corrosion on Underground or Submerged Metallic Piping Systems 4.5.3.1.(1) NFPA 10-2013 Standard for Portable Fire Extinguishers 6.2.7.1.(1) and (2) NFPA 11-2016 Standard for Low-, Medium-, and High-Expansion Foam 2.1.3.5.(3) 4.3.2.5.(2) NFPA 12-2015 Standard on Carbon Dioxide Extinguishing Systems 2.1.3.5.(3) NFPA 12A-2015 Standard on Halon 1301 Fire Extinguishing Systems 2.1.3.5.(3) NFPA 12B-1990 Standard on Halon 1211 Fire Extinguishing Systems 2.1.3.5.(3) NFPA 13-2019 Standard for the Installation of Sprinkler Systems 3.2.1.8.(1) 3.2.1.9. 3.2.2.2.(5) 3.2.2.10.(3) 3.2.3.6.(1) 3.2.4.3.(4) 3.2.5.5.(1) 3.2.7.5.(3) 3.2.7.9.(1) 3.2.7.20. 4.2.8.4.(2) 4.9.4.3.(4) 5.4.2.3. 5.4.5.1. 5.12.8.2.(1) 5.13.6.1. 6.5.1.1.(1) 9.2.5.2.(4) Table 9.2.5.A. 9.4.5.5.(2) 9.5.5.3.(2) 9.6.5.5.(2) 9.7.5.1.(1) and (4) NFPA 13D-2016 Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes 6.5.1.1.(1) 9.7.5.1.(2) 9.8.5.1. NFPA 13R-2019 Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height 6.5.1.1.(1) 9.4.5.5.(3) 9.5.5.3.(2) 9.7.5.1.(3) NFPA 15-2017 Standard for Water Spray Fixed Systems for Fire Protection 2.1.3.5.(4) 4.3.2.5.(2) NFPA 16-2019 Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems 2.1.3.5.(4) NFPA 17-2017 Standard for Dry Chemical Extinguishing Systems 2.1.3.5.(3) NFPA 17A-2017 Standard for Wet Chemical Extinguishing Systems 2.1.3.5.(3) NFPA 18-2017 Standard on Wetting Agents 2.1.3.5.(5) NFPA 20-2016 Standard for the Installation of Stationary Pumps for Fire Protection 9.4.5.5.(5) 9.7.5.1.(6) NFPA 24-2013 Standard for the Installation of Private Fire Service Mains and their Appurtenances 4.9.4.3.(4) NFPA 25-2017 Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems 6.4.1.6. 6.5.1.1.(2) 6.6.1.5.(1) to (3) NFPA 30-2018 Flammable and Combustible Liquids Code 4.2.7.6.(1) 4.3.16.1.(1) 4.3.16.6.(1) NFPA 30B-2019 Code for the Manufacture and Storage of Aerosol Products 3.2.5.2. 3.2.5.5.(1) NFPA 32-2016 Standard for Drycleaning Plants 5.14.10.1.(1) NFPA 33-2018 Standard for Spray Application Using Flammable or Combustible Materials 5.12.1.1.(2) 5.12.3.5. 5.12.8.2.(2) 5.14.4.1.(2) 5.14.6.1.(3) NFPA 37 2018 Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines 4.3.13.2. NFPA 40-2022 Standard for the Storage and Handling of Cellulose Nitrate Motion Picture Film 5.4.4.2. NFPA 40E-1993 Code for the Storage of Pyroxylin Plastic 5.4.3.3.(1) NFPA 51-2018 Standard for Design and Installation of Oxygen-Fuel Gas Systems for Welding, Cutting and Allied Processes 5.17.2.1. NFPA 55-2020 Compressed Gases and Cryogenic Fluids Code 5.6.1.1.(3) and (8) NFPA 68-2013 Standard on Explosion Protection by Deflagration Venting 4.2.9.5. 4.3.14.3. 4.9.3.1. 4.9.4.2.(1) 5.3.1.6.(2) 5.6.2.4.(1) 5.18.3.3.(2) and (3) NFPA 69 2014 Standard on Explosion Prevention Systems 4.3.2.5.(2) 4.9.4.2.(1) 5.3.1.7.(2) NFPA 71-1989 Standard for the Installation, Maintenance and Use of Signaling Systems for Central Station Service 6.3.1.2.(2) NFPA 72-2019 National Fire Alarm and Signaling Code 6.3.1.2.(5) NFPA 82-2014 Standard on Incinerators and Waste and Linen Handling Systems and Equipment 2.6.3.1.(2) 2.6.3.2. NFPA 86-2019 Standard for Ovens and Furnaces 4.5.8.5.(2) 5.18.4.1. NFPA 91-2015 Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids 4.1.7.2.(5) 5.1.4.2.(1) 5.5.4.3.(1) NFPA 96-2014 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2.6.1.12.(1) 2.6.1.13. NFPA 291-2022 Recommended Practice for Fire Flow Testing and Marking of Hydrants 6.6.6.1. NFPA 505-2018 Fire Safety Standard for Powered Industrial Trucks Including Type Designations, Areas of Use, Conversions, Maintenance, and Operation 3.4.1.1. NFPA 664-2017 Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities 5.3.2.1.(1) NFPA 705-2018 Recommended Practice for a Field Flame Test for Textiles and Films 2.3.2.2. 2.9.2.1. NFPA 1142-2022 Standard on Water Supplies for Suburban and Rural Fire Fighting 3.3.1.9.(4) NFPA 2001-2022 Standard on Clean Agent Fire Extinguishing Systems 2.1.3.5.(3) NRCan Edition 3, 2014 Special Effects Pyrotechnics Manual 5.1.1.3. NRCan Second Edition, 2010 Display Fireworks Manual 5.1.1.3. NRCC User’s Guide - NBC 1995 Fire Protection, Occupant Safety and Accessibility (Part 3) 7.3.1.2. OFM Fire Code Supplement FCS-1, February 2025 Objectives and Functional Statements Attributed to the Acceptable Solutions 1.2.2.1.(1), (2) and (3) of Division A 1.3.2.2.(1) and (2) of Division C STI/SPFA SP031-2008 Standard for Repair of Shop Fabricated Aboveground Tanks for Storage of Flammable and Combustible Liquids 4.3.1.10.(2) TC 2001 Standards Respecting Pipeline Crossings Under Railways 4.5.6.5.(3) UL ANSI/UL 558-1998 Industrial Trucks, Internal Combustion Engine‑Powered 3.4.2.1.(3) UL UL 2034-2008 Single and Multiple Station Carbon Monoxide Alarms 2.16.2.1.(6) 6.3.4.7.(4) ULC ANSI/CAN/UL/ULC 2258:2018 Standard for Aboveground Nonmetallic Tanks for Fuel Oil and Other Combustible Liquids 4.3.1.2.(1) ULC CAN/ULC-S109-14 Standard for Flame Tests of Flame-Resistant Fabrics and Films 2.3.2.1.(1) ULC ULC-S505-1974 Standard for Fusible Links for Fire Protection Service 9.5.3.7.(5) ULC CAN/ULC-S508-02 Standard for the Rating and Testing of Fire Extinguishers 6.2.2.1. ULC CAN/ULC-S524-2019 Standard for the Installation of Fire Alarm Systems 6.3.1.8. 9.9.4.12.(1) ULC CAN/ULC-S531-2019 Standard for Smoke Alarms 2.13.2.1.(3) 9.3.4.5.(3) 9.5.4.5.(3) 9.6.4.10.(3) 9.7.4.3.(4) 9.8.4.2.(3) 9.9.4.13.(2) ULC CAN/ULC-S536-2019 Standard for Inspection and Testing of Fire Alarm Systems 6.3.2.2.(1) to (3) 6.3.2.4. ULC CAN/ULC-S537-2019 Standard for Verification of Fire Alarm Systems 9.9.4.12.(2) ULC CAN/ULC-S540-13 Standard for Residential Fire and Life Safety Warning Systems: Installation, Inspection, Testing and Maintenance 2.13.2.1.(4) ULC CAN/ULC-S552-14 Standard for the Maintenance and Testing of Smoke-Alarms 6.3.2.6.(2) ULC CAN/ULC-S553-14 Standard for the Installation of Smoke-Alarms 9.3.4.5.(3) 9.5.4.5.(3) 9.6.4.10.(3) 9.7.4.3.(5) 9.8.4.2.(3) 9.9.4.13.(2) ULC CAN/ULC-S561-13 Standard for Installation and Services for Fire Signal Receiving Centres and Systems 6.3.1.2.(2) 9.7.4.1.(2) 9.7.4.2.(2) ULC CAN/ULC S601 14 Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids 4.3.1.2.(1) 4.3.3.2.(1) 4.3.7.4.(2) 4.3.13.5.(1) ULC CAN/ULC S602 14 Standard for Steel Aboveground Tanks for Fuel Oil and Lubricating Oil 4.3.1.2.(1) ULC ULC S60

    The text continues in the official source.

    © King's Printer for Ontario, see first-publication year in the official source. Reproduced accurately; this is not an official copy.

    Related guides, FAQ and contract templates